CT PT Test Equipment
(37)
CT PT 220KV Portable Test Equipment With PC Communication Interface
Price: Negotiable
MOQ: 1
Delivery Time: 30-45 days
Brand: HNMC
High Light:0.01S Class 5000A Portable Test Equipment, 0.01S Class Portable Test Equipment, 220KV 0.01S Class current potential transformer
CT PT TEST Equipment System HES-30 Configuration Standard CT, ±0.01S% Standard PT (6kV-38.5kV), ±0.05% Standard PT (110/√3kV, 220/√3kV), ±0.05% CT Burden (5A, 1A), ±3% PT Burden (100V, 100/√3V, 100/3V), ±3% PT Burden (110V, 110/√3V, 110/3V), ±3% Transformer Tester (Calibrator), ±2% Current generator... View More
➤ Visit Website

1A Current Transformer Test Equipment , 0.02S Current Transformer Tester
Price: Negotiable
MOQ: 1
Delivery Time: 30-45 days
Brand: HNMC
High Light:1A Current Transformer Test Equipment, 120V Current Transformer Test Equipment, 0.02S Current Transformer Tester
0.02S Standard Current Transformer CT PT Test Equipment Test System Measure Item Test Range CT accuracy test Rated primary current range: 1A-3200A Rated secondary current: 5A, 1A Operation range: (1%-120%).In PT accuracy test Rated primary voltage (kV): 6, 6/√3, 10, 10/√3, 15, 15/√3, 22, 22/√3, 35, ... View More
➤ Visit Website

0.1% Transformer Turns Ratio Test Kit , 500VA CT PT Analyzer
Price: Negotiable
MOQ: 1
Delivery Time: 30-45 days
Brand: HNMC
High Light:500VA 0.1% Transformer Turns Ratio Test Kit, lab 500VA Transformer Turns Ratio Test Kit, 500VA CT PT Analyzer
Porable CT PT Test Equipment Analyzer MCVT405 Main Features CT Test PT Test 1) Excitation curve and parameters test 2) Turns ratio test 3) Ratio and phase error test 4) Polarity mark check 5) Winding resistance measurement 6) Secondary burden measurement 7) Error line curve test for protection CT 8)... View More
➤ Visit Website

360KV CT PT Test Equipment , Utility Instrument Transformer Test Set
Price: Negotiable
MOQ: 1
Delivery Time: 30-45 days
Brand: HNMC
High Light:360KV CT PT Test Equipment, Resonance CT PT Test Equipment, 360KV Utility Instrument Transformer Test Set
360KV Resonance High Voltage Source CVT Test System HEW-30 Testing system configuration No Description 1 Testing Bench 2 Exciting Transformer 3 Reactor 4 Testing Cable 5 Accessories General specification: Product Application: The system is a voltage generator, and used for Capacitive PT accuracy tes... View More
➤ Visit Website

Cabinet Type CT PT Test Equipment System Error Measurement
Price: Negotiable
MOQ: 1
Delivery Time: 30-45 days
Brand: HNMC
High Light:5000A CT PT Test Equipment, 35KV CT PT Test Equipment, 0.02% current transformer analyzer
Cabinet Type CT PT Test Bench System MCHZDZ-3Z System Configuration 1) HZDT Fully automatic Cabinet type Control Bench 2) Digital Transformer Tester 3) Current Transformer Burden (5A/1A optional) 4) Standard Current Transformer ( with Current Source) 5) Voltage Transformer Burden 6) Standard Voltage... View More
➤ Visit Website

Standard Current Transformer
Price: Negotiable
MOQ: 1
Delivery Time: Negotiable
Standard CT Rated primary current : 5A-1000A,5A-2000A,5A-3150A,5A-5000A (or other rated primary current value ) Reference value of rated primary current (A): 5,7.5,10,12.5,15,20,25,30,40,50,60,75,80,100,120,125,150,160,200,250,300,315,350,400,450,500,600,630,750,800,900,1000,1200,1250,1400,1500,1600... View More
➤ Visit Website

Phase Angle Error CT PT Test Set
Price: Negotiable
MOQ: 1
Delivery Time: 30-45 days
Brand: HNMC
High Light:1.5%FS CT PT Test Set, 1.5%FS 100V CT PT Test Set, 5A 1.5%FS ratio ct and pt testing
Digital Transformer Tester HEWE series CT PT Test Equipment Comparator Technical Parameter Accuracy class 2 Current range 5A, 1A Voltage range 100V,100/√3V Percentage Error Less than 1.5%*FS Basic Error When testing CT PT error & impedance & admittance, the error will not beyond: ΔX=±(X*2%+Y... View More
➤ Visit Website

0.02 Class CT PT Test Equipment
Price: Negotiable
MOQ: 1
Delivery Time: 30-45 days
Brand: HNMC
High Light:0.02 Class Portable CT PT Test Equipment, 60Hz 0.02 Class CT PT Test Equipment, 0.02 Class Capacitance PT Tester
Portable Capacitance PT Test Equipment MCVT01 Technical Index Accuracy class 0.02 Primary voltage range 35/√3 – 500/√3 kV Secondary voltage 100/√3, 100, 100/3 V Secondary burden range 2.5 – 300VA Power factor 0.8, 1 Rated frequency 50 or 60Hz Power capacity 500VA Features 1) Adopting indirect method... View More
➤ Visit Website

0.05S CT PT Analyzer
Price: Negotiable
MOQ: 1
Delivery Time: 30-45 days
Brand: HNMC
High Light:25000A 0.05S CT PT Analyzer, 25000A CT PT Analyzer, Ratio Error 25000A pt ct test
Portable CT Field Test Equipment MCT01 Features 1) Portable Equipment with function equal to test bench 2) Integrating standard PT, voltage generator, electronic power source and comparator together 3) Can test CT with accuracy class 1 – class 0.2S, only turns compensation or fraction turns compensa... View More
➤ Visit Website

Portable 0.05 Class Transformer Ratio Tester For Field
Price: Negotiable
MOQ: 1
Delivery Time: 30-45 days
Brand: HNMC
High Light:0.05 Class Transformer Ratio Tester, Transformer Ratio Tester For Field, 0.05 Class transformer turns ratio meter
Portable CT PT Test Equipment MCVT-01D Major Technical Parameters Major Technical Parameters Operational Power Supply: AC220V±20V, 50~60Hz Equipment Power Supply Output Waveform: Sine Wave Single Machine Output Voltage of Excitation Characteristic: 0~2500V Excitation Current Set: 0~20 A Single Machi... View More
➤ Visit Website

0.01S Class Standard 5000A 38.5KV CT PT Test Equipment System
Price: Negotiable
MOQ: 1
Delivery Time: 30-45 days
Brand: HNMC
High Light:38.5KV CT PT Test Equipment, 5000A CT PT Test Equipment, 0.01S CT PT Test Equipment
CT PT TEST Equipment System HES-30 Configuration Standard CT, ±0.01S% Standard PT (6kV-38.5kV), ±0.05% CT Burden (5A, 1A), ±3% PT Burden (100V, 100/√3V, 100/3V), ±3% PT Burden (110V, 110/√3V, 110/3V), ±3% Transformer Tester (Calibrator), ±2% Current generator Voltage Generator Secondary Test Cables ... View More
➤ Visit Website

0.01S Class CT PT Test Equipment , 220KV Current Transformer Test Set
Price: Negotiable
MOQ: 1
Delivery Time: 30-45 days
Brand: HNMC
High Light:5000A 220KV CT PT Test Equipment, 5000A CT PT Test Equipment, 0.01S Current Transformer Test Set
CT PT TEST Equipment System HES-30 Technical Parameter HES-30 CT/PT Test Bench Input Voltage: AC 220V±10%, 50Hz, Single-Phase Input Current: AC 0-120A Rated Capacity: 30kVA Output Voltage: AC 0-250V Output Current: AC 0-120A HES-1Bx Transformer Tester Measure item: Ratio errors & Phase errors of... View More
➤ Visit Website

0.001 Class CT PT Test Equipment Stable Reliable Output
Price: Negotiable
MOQ: 1
Delivery Time: 30-45 days
Brand: HNMC
High Light:0.001 Class CT PT Test Equipment, 50Hz CT PT Test Equipment, 0.001 Class Lab pt ct test
Induction Voltage Divider HJF3 1. Usage HJF3 type induction voltage divider is used for testing and calibration of voltage transformer whose ratio is different from standard voltage transformer. In general, the secondary load of standard VT is 0.2VA(100V) or 0.07VA(100/√3V); total exciting power of ... View More
➤ Visit Website

Portable 0.05 Class Transformer Ratio Tester For Field Examianation
Price: Negotiable
MOQ: 1
Delivery Time: 30-45 days
Brand: HNMC
High Light:0.05 Class Transformer Ratio Tester, Portable Transformer Ratio Tester, Field CT PT Testing Equipment
Portable CT PT Test Equipment MCVT-01D Major Technical Parameters Item Description Power Supply AC220V±10% 50/60HZ Output 0-180Vrms, 12Arms, 36A (peak value) Voltage test accuracy ±0.2% Ratio error test (metering CT) ±0.2% Secondary resistance range/accuracy 0~300Ω / 0.2%±2mΩ Secondary burden range/... View More
➤ Visit Website

Automatic Calculation CT Ratio Tester , 600A CT PT Analyser
Price: Negotiable
MOQ: 1
Delivery Time: 30-45 days
Brand: HNMC
High Light:500VA CT Ratio Tester, 500VA 0.02 Class CT Ratio Tester, 600A 500VA CT PT Analyser
CT PT Analyzer Test Equipment MCVT-01C Major Technical Parameters Item Description Power Supply AC220V±10% 50/60HZ Output 0-2500Vrms, 5Arms, 20A (peak value) Big current output 0-600A Excitation accuracy ≤0.2% Secondary winding resistance range/accuracy 0~300Ω / ≤0.2% Secondary burden range/accuracy... View More
➤ Visit Website

Digital Portable Testing Equipment , IEC61850 Transformer Test Set
Price: Negotiable
MOQ: 1
Delivery Time: 30-45 days
Brand: HNMC
High Light:0.05% Portable Testing Equipment, Digital Portable Testing Equipment, IEC61850 Transformer Test Set
Digital CT VT Tester/Calibrator HEWD-2A Technical Parameter Rated Primary voltage measureup to 500KVRated primary current measure5-5000A, customization availableStandard signal inputVoltage input0-120%Un, Un=100V,100/√3V. Customization availableCurrent input0-120%In, In=1A or 5A. Customization avail... View More
➤ Visit Website

0.2 Class CT PT Test Equipment Electromagnetic Type VT
Price: Negotiable
MOQ: 1
Delivery Time: 10-25 days
Brand: HNMC
High Light:0.2 Class CT PT Test Equipment, 0.2 Class Field CT PT Test Equipment, Ratio 0.2 Class CT Polarity Tester
CT/PT Ratio & Polarity Tester MCVT-RP01 Technical Index Ratio test range 5A/5A-25000A/5A, 5A/1A-5000A/1A Test object type various CT and all electromagnetic type VT Test accuracy 0.2% Dimension 280*230*100mm Weight 3kGS Features 1) Adopting voltage method for measurement, small size and light we... View More
➤ Visit Website

High Voltage Source CVT Testing , 60HZ Capacitive Voltage Transformer Testing
Price: Negotiable
MOQ: 1
Delivery Time: 30-45 days
Brand: HNMC
High Light:60HZ High Voltage Source CVT Testing, 60HZ 200KVA CVT Testing, 60HZ Capacitive Voltage Transformer Testing
200KV High Voltage Source & Control Cabinet HEW-20 CVT Test System Testing system configuration No Product Description 1 Control Cabinet 2 Testing Transformer 3 Testing Cables General Specification Product Application: The system is a voltage generator system, and used for 110/√3kV and 220/√3kV ... View More
➤ Visit Website

0.01 Class Current Potential Transformer With Generator Double Stages
Price: Negotiable
MOQ: 1
Delivery Time: 30-45 days
Brand: HNMC
High Light:10KV 0.01 Class Current Potential Transformer, 0.01 Class 0.2VA Current Potential Transformer, 0.01 Class Ct Pt Transformer
0.01 Class Double Stage Standard PT with voltage Generator Technical Parameter Rated voltage ratio 6,10,35Kv/100V, 6,10,35/√3Kv /100/√3V Rated secondary capacity 0.2VA,0.07VA CosФ=1.0 Accuracy class 0.05, 0.02, 0.01 withstand voltage level Induction withstand voltage 1.2Un/1min; Secondary to Ground ... View More
➤ Visit Website

Automatic Voltage Transformer Burden With Air Insulation
Price: Negotiable
MOQ: 1
Delivery Time: 30-45 days
Brand: HNMC
High Light:Automatic Voltage Transformer Burden, 110V Voltage Transformer Burden, 3% transformer testing equipment
Manual or Automatic CT VT Burden box FYC series FYC47-49 CT Burden Technical Parameter Rated Current: 5A, 1A Power Factor and Rated Burden: COSΦ=0.8: 5VA, 10VA, 15VA, 20VA, 30VA COSΦ=1.0: 1VA, 2VA, 5VA Accuracy Class: ±3% Operation Range: (1%-200%). In Test Cable Resistance: 0.02Ω Frequency: 50Hz Wi... View More